| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| Automox Agent prior to version 37 on Windows and Linux and Version 36 on OSX could allow for a non privileged user to obtain sensitive information during the install process. |
| Mastodon before 3.3.2 and 3.4.x before 3.4.6 has incorrect access control because it does not compact incoming signed JSON-LD activities. (JSON-LD signing has been supported since version 1.6.0.) |
| Zoho ManageEngine SharePoint Manager Plus before 4329 allows account takeover because authorization is mishandled. |
| Zoho ManageEngine SharePoint Manager Plus before 4329 is vulnerable to a sensitive data leak that leads to privilege escalation. |
| Pillow before 9.0.1 allows attackers to delete files because spaces in temporary pathnames are mishandled. |
| In Minetest before 5.4.0, players can add or subtract items from a different player's inventory. |
| Minetest before 5.4.0 allows attackers to add or modify arbitrary meta fields of the same item stack as saved user input, aka ItemStack meta injection. |
| Improper input validation vulnerability in pfSense CE and pfSense Plus (pfSense CE software versions prior to 2.6.0 and pfSense Plus software versions prior to 22.01) allows a remote attacker with the privilege to change OpenVPN client or server settings to execute an arbitrary command. |
| Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications. |
| Okta Advanced Server Access Client for Windows prior to version 1.57.0 was found to be vulnerable to command injection via a specially crafted URL. |
| A regular expression used in Apache MXNet (incubating) is vulnerable to a potential denial-of-service by excessive resource consumption. The bug could be exploited when loading a model in Apache MXNet that has a specially crafted operator name that would cause the regular expression evaluation to use excessive resources to attempt a match. This issue affects Apache MXNet versions prior to 1.9.1. |
| Certain HP Print devices may be vulnerable to potential information disclosure, denial of service, or remote code execution. |
| Certain HP Print devices may be vulnerable to potential information disclosure, denial of service, or remote code execution. |