| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Televes COAXDATA GATEWAY 1Gbps devices doc-wifi-hgw_v1.02.0014 4.20 do not check password.shtml authorization, leading to Arbitrary password change. |
| An issue was discovered in ABOOT in OnePlus 3 and 3T OxygenOS before 4.0.2. The attacker can reboot the device into the fastboot mode, which could be done without any authentication. A physical attacker can press the "Volume Up" button during device boot, where an attacker with ADB access can issue the adb reboot bootloader command. Then, the attacker can put the platform's SELinux in permissive mode, which severely weakens it, by issuing: fastboot oem selinux permissive. |
| The web/web_file/fb_publish.php script in D-Link DNS-320L before 1.04b12 and DNS-327L before 1.03b04 Build0119 does not authenticate requests, which allows remote attackers to obtain arbitrary photos and publish them to an arbitrary Facebook profile via a target album_id and access_token. |
| The Toshiba FlashAir SD-WD/WC series Class 6 model with firmware version 1.00.04 and later, FlashAir SD-WD/WC series Class 10 model W-02 with firmware version 2.00.02 and later, FlashAir SD-WE series Class 10 model W-03, FlashAir Class 6 model with firmware version 1.00.04 and later, FlashAir II Class 10 model W-02 series with firmware version 2.00.02 and later, FlashAir III Class 10 model W-03 series, FlashAir Class 6 model with firmware version 1.00.04 and later, FlashAir W-02 series Class 10 model with firmware version 2.00.02 and later, FlashAir W-03 series Class 10 model does not require authentication on accepting a connection from STA side LAN when "Internet pass-thru Mode" is enabled, which allows attackers with access to STA side LAN can obtain files or data. |
| In Pivotal Spring-LDAP versions 1.3.0 - 2.3.1, when connected to some LDAP servers, when no additional attributes are bound, and when using LDAP BindAuthenticator with org.springframework.ldap.core.support.DefaultTlsDirContextAuthenticationStrategy as the authentication strategy, and setting userSearch, authentication is allowed with an arbitrary password when the username is correct. This occurs because some LDAP vendors require an explicit operation for the LDAP bind to take effect. |
| forgotpassword.php in GeniXCMS 1.0.2 lacks a rate limit, which might allow remote attackers to cause a denial of service (login inability) or possibly conduct Arbitrary User Password Reset attacks via a series of requests. |
| A vulnerability in the session identification management functionality of the web-based GUI of Cisco Integrated Management Controller (IMC) 3.0(1c) could allow an unauthenticated, remote attacker to hijack a valid user session on an affected system. The vulnerability exists because the affected software does not assign a new session identifier to a user session when a user authenticates to the web-based GUI. An attacker could exploit this vulnerability by using a hijacked session identifier to connect to the software through the web-based GUI. A successful exploit could allow the attacker to hijack an authenticated user's browser session on the affected system. Cisco Bug IDs: CSCvd14583. |
| HOME SPOT CUBE2 firmware V101 and earlier allows an attacker to bypass authentication to load malicious firmware via WebUI. |
| An insufficient authentication vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unprivileged, authenticated, user to execute certain specific unprivileged system files capable of causing widespread denials of system services. |
| Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings. |
| An issue was discovered in SMA Solar Technology products. The SMAdata2+ communication protocol does not properly use authentication with encryption: it is vulnerable to man in the middle, packet injection, and replay attacks. Any setting change, authentication packet, scouting packet, etc. can be replayed, injected, or used for a man in the middle session. All functionalities available in Sunny Explorer can effectively be done from anywhere within the network as long as an attacker gets the packet setup correctly. This includes the authentication process for all (including hidden) access levels and the changing of settings in accordance with the gained access rights. Furthermore, because the SMAdata2+ communication channel is unencrypted, an attacker capable of understanding the protocol can eavesdrop on communications. NOTE: the vendor's position is that authentication with encryption is not required on an isolated subnetwork. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating. |
| WAPM-1166D firmware Ver.1.2.7 and earlier, WAPM-APG600H firmware Ver.1.16.1 and earlier allows remote attackers to bypass authentication and access the configuration interface via unspecified vectors. |
| Some Huawei smart phones with software Berlin-L21C10B130,Berlin-L21C185B133,Berlin-L21HNC10B131,Berlin-L21HNC185B140,Berlin-L21HNC432B151,Berlin-L22C636B160,Berlin-L22HNC636B130,Berlin-L22HNC675B150CUSTC675D001,Berlin-L23C605B131,Berlin-L24HNC567B110,FRD-L02C432B120,FRD-L02C635B130,FRD-L02C675B170CUSTC675D001,FRD-L04C567B162,FRD-L04C605B131,FRD-L09C10B130,FRD-L09C185B130,FRD-L09C432B131,FRD-L09C636B130,FRD-L14C567B162,FRD-L19C10B130,FRD-L19C432B131,FRD-L19C636B130 have a factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the configuration flow by Swype Keyboard and can perform some operations to update the Google account. As a result, the FRP function is bypassed. |
| A vulnerability in the implementation of Protected Extensible Authentication Protocol (PEAP) functionality for standalone configurations of Cisco Aironet 1800, 2800, and 3800 Series Access Points could allow an unauthenticated, adjacent attacker to bypass authentication and connect to an affected device. The vulnerability exists because the affected device uses an incorrect default configuration setting of fail open when running in standalone mode. An attacker could exploit this vulnerability by attempting to connect to an affected device. A successful exploit could allow the attacker to bypass authentication and connect to the affected device. This vulnerability affects Cisco Aironet 1800, 2800, and 3800 Series Access Points that are running a vulnerable software release and use WLAN configuration settings that include FlexConnect local switching and central authentication with MAC filtering. Cisco Bug IDs: CSCvd46314. |
| An attacker that has hijacked a Unitrends Enterprise Backup (before 9.1.2) web server session can leverage api/includes/users.php to change the password of the logged in account without knowing the current password. This allows for an account takeover. |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations. |
| A vulnerability in ipsilon 2.0 before 2.0.2, 1.2 before 1.2.1, 1.1 before 1.1.2, and 1.0 before 1.0.3 was found that allows attacker to log out active sessions of other users. This issue is related to how it tracks sessions, and allows an unauthenticated attacker to view and terminate active sessions from other users. It is also called a "SAML2 multi-session vulnerability." |
| CAPTCHA bypass vulnerability in MantisBT before 1.2.19. |
| An Improper Authentication issue was discovered in PDQ Manufacturing LaserWash G5 and G5 S Series all versions, LaserWash M5, all versions, LaserWash 360 and 360 Plus, all versions, LaserWash AutoXpress and AutoExpress Plus, all versions, LaserJet, all versions, ProTouch Tandem, all versions, ProTouch ICON, all versions, and ProTouch AutoGloss, all versions. The web server does not properly verify that provided authentication information is correct. |