A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can gain remote code execution by sending specifically crafted objects to one of its functions. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Search vulnerabilities
In Omron PLC CS series, all versions, Omron PLC CJ series, all versions, and Omron PLC NJ series, all versions, the software does not implement sufficient measures to prevent multiple failed authentication attempts within in a short time frame, making it more susceptible to brute force attacks.
In Omron PLC CJ series, all versions and Omron PLC CS series, all versions, an attacker could spoof arbitrary messages or execute commands.
In Advantech DiagAnywhere Server, Versions 3.07.11 and prior, multiple stack-based buffer overflow vulnerabilities exist in the file transfer service listening on the TCP port. Successful exploitation could allow an unauthenticated attacker to execute arbitrary code with the privileges of the user running DiagAnywhere Server.
An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series (versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior) outside the intended directory.
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code.
Advantech Spectre RT ERT351 Versions 5.1.3 and prior has insufficient login authentication parameters required for the web application may allow an attacker to gain full access using a brute-force password attack.
Equinox Control Expert all versions, is vulnerable to an SQL injection attack, which may allow an attacker to remotely execute arbitrary code.
Honeywell equIP series and Performance series IP cameras and recorders, A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products.
An issue was discovered in Citrix Application Delivery Controller (ADC) and Gateway before 10.5 build 70.8, 11.x before 11.1 build 63.9, 12.0 before build 62.10, 12.1 before build 54.16, and 13.0 before build 41.28. An attacker with management-interface access can bypass authentication to obtain appliance administrative access. These products formerly used the NetScaler brand name.
An issue was discovered on Fujitsu Wireless Keyboard Set LX390 GK381 devices. Because of the lack of proper encryption of 2.4 GHz communication, they are prone to keystroke injection attacks.
Trend Micro Security (Consumer) 2020 (v16.x) is affected by a vulnerability in where null pointer dereference errors result in the crash of application, which could potentially lead to possible unsigned code execution under certain circumstances.
A directory traversal vulnerability in Trend Micro Apex One, OfficeScan (11.0, XG) and Worry-Free Business Security (9.5, 10.0) may allow an attacker to bypass authentication and log on to an affected product's management console as a root user. The vulnerability does not require authentication.
pacman before 5.2 is vulnerable to arbitrary command injection in lib/libalpm/sync.c in the apply_deltas() function. This can be exploited when unsigned databases are used. To exploit the vulnerability, the user must enable the non-default delta feature and retrieve an attacker-controlled crafted database and delta file.
pacman before 5.2 is vulnerable to arbitrary command injection in conf.c in the download_with_xfercommand() function. This can be exploited when unsigned databases are used. To exploit the vulnerability, the user must enable a non-default XferCommand and retrieve an attacker-controlled crafted database and package.
WordPress before 5.2.4 has a Server Side Request Forgery (SSRF) vulnerability because Windows paths are mishandled during certain validation of relative URLs.
WordPress before 5.2.4 has a Server Side Request Forgery (SSRF) vulnerability because URL validation does not consider the interpretation of a name as a series of hex characters.
ThinVNC 1.0b1 is vulnerable to arbitrary file read, which leads to a compromise of the VNC server. The vulnerability exists even when authentication is turned on during the deployment of the VNC server. The password for authentication is stored in cleartext in a file that can be read via a ../../ThinVnc.ini directory traversal attack vector.
An unquoted service path vulnerability in the FortiClient FortiTray component of FortiClientWindows v6.2.2 and prior allow an attacker to gain elevated privileges via the FortiClientConsole executable service path.