A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
Search vulnerabilities
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Automox Agent prior to version 37 on Windows and Linux and Version 36 on OSX could allow for a non privileged user to obtain sensitive information during the install process.
Mastodon before 3.3.2 and 3.4.x before 3.4.6 has incorrect access control because it does not compact incoming signed JSON-LD activities. (JSON-LD signing has been supported since version 1.6.0.)
Zoho ManageEngine SharePoint Manager Plus before 4329 allows account takeover because authorization is mishandled.
Zoho ManageEngine SharePoint Manager Plus before 4329 is vulnerable to a sensitive data leak that leads to privilege escalation.
python-pillow: temporary directory with a space character allows removal of unrelated file after im.show() and related actions
Pillow before 9.0.1 allows attackers to delete files because spaces in temporary pathnames are mishandled.
In Minetest before 5.4.0, players can add or subtract items from a different player's inventory.
Minetest before 5.4.0 allows attackers to add or modify arbitrary meta fields of the same item stack as saved user input, aka ItemStack meta injection.
Improper input validation vulnerability in pfSense CE and pfSense Plus (pfSense CE software versions prior to 2.6.0 and pfSense Plus software versions prior to 22.01) allows a remote attacker with the privilege to change OpenVPN client or server settings to execute an arbitrary command.
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.
Okta Advanced Server Access Client for Windows prior to version 1.57.0 was found to be vulnerable to command injection via a specially crafted URL.
ReDoS in Apache MXNet RTC Module
A regular expression used in Apache MXNet (incubating) is vulnerable to a potential denial-of-service by excessive resource consumption. The bug could be exploited when loading a model in Apache MXNet that has a specially crafted operator name that would cause the regular expression evaluation to use excessive resources to attempt a match. This issue affects Apache MXNet versions prior to 1.9.1.