CVE-2020-6967

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

CVSS 3.1 · 9.8 Critical EPSS 5.5% KEV · Not listed
CVE-2020-6966

In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.

CVSS 3.1 · 10.0 Critical EPSS 2.2% KEV · Not listed
Vendors
CVE-2020-6965

In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.

CVSS 3.1 · 9.9 Critical EPSS 1.1% KEV · Not listed
Vendors
CVE-2020-6964

In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.

CVSS 3.1 · 8.6 High EPSS 1.4% KEV · Not listed
Vendors
CVE-2020-6963

In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.

CVSS 3.1 · 10.0 Critical EPSS 2.7% KEV · Not listed
Vendors
CVE-2020-6962

In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.

CVSS 3.1 · 10.0 Critical EPSS 4.9% KEV · Not listed
Vendors
CVE-2020-6961

In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.

CVSS 3.1 · 10.0 Critical EPSS 1.6% KEV · Not listed
Vendors
CVE-2020-6960

The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch contain an SQL injection vulnerability that could give an attacker remote unauthenticated access to the web user interface with administrator-level privileges.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2020-6959

The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch are vulnerable to an unsafe deserialization of untrusted data. An attacker may be able to remotely modify deserialized data without authentication using a specially crafted web request, resulting in remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 2.2% KEV · Not listed
Vendors
Products
CVE-2020-6954

An issue was discovered on Cayin SMP-PRO4 devices. A user can discover a saved password by viewing the URL after a Connection String Test. This password is shown in the webpass parameter of a media_folder.cgi?apply_mode=ping_server URI.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-6949

A privilege escalation issue was discovered in the postUser function in HashBrown CMS through 1.3.3. An editor user can change the password hash of an admin user's account, or otherwise reconfigure that account.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2020-6948

A remote code execution issue was discovered in HashBrown CMS through 1.3.3. Server/Entity/Deployer/GitDeployer.js has a Service.AppService.exec call that mishandles the URL, repository, username, and password.

CVSS 3.1 · 9.8 Critical EPSS 2.8% KEV · Not listed
Vendors
Products
CVE-2020-6939

Tableau Server installations configured with Site-Specific SAML that allows the APIs to be used by unauthenticated users. If exploited, this could allow a malicious user to configure Site-Specific SAML settings and could lead to account takeover for users of that site. Tableau Server versions affected on both Windows and Linux are: 2018.2 through 2018.2.27, 2018.3 through 2018.3.24, 2019.1 through 2019.1.22, 2019.2 through 2019.2.18, 2019.3 through 2019.3.14, 2019.4 through 2019.4.13, 2020.1 through 2020.1.10, 2020.2 through 2020.2.7, and 2020.3 through 2020.3.2.

CVSS 3.1 · 9.8 Critical EPSS 1.8% KEV · Not listed
Vendors