Search vulnerabilities

Results 426,156

CVE-2020-12059

ceph: specially crafted XML payload on POST requests leads to DoS by crashing RGW

An issue was discovered in Ceph through 13.2.9. A POST request with an invalid tagging XML can crash the RGW process by triggering a NULL pointer exception.

CVSS 3.1 · 7.5 High EPSS 2.4% KEV · Not listed
CVE-2020-12058

Several XSS vulnerabilities in osCommerce CE Phoenix before 1.0.6.0 allow an attacker to inject and execute arbitrary JavaScript code. The malicious code can be injected as follows: the page parameter to catalog/admin/order_status.php, catalog/admin/tax_rates.php, catalog/admin/languages.php, catalog/admin/countries.php, catalog/admin/tax_classes.php, catalog/admin/reviews.php, or catalog/admin/zones.php; or the zpage or spage parameter to catalog/admin/geo_zones.php.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-12054

The Catch Breadcrumb plugin before 1.5.4 for WordPress allows Reflected XSS via the s parameter (a search query). Also affected are 16 themes (if the plugin is enabled) by the same author: Alchemist and Alchemist PRO, Izabel and Izabel PRO, Chique and Chique PRO, Clean Enterprise and Clean Enterprise PRO, Bold Photography PRO, Intuitive PRO, Devotepress PRO, Clean Blocks PRO, Foodoholic PRO, Catch Mag PRO, Catch Wedding PRO, and Higher Education PRO.

CVSS 3.1 · 6.1 Medium EPSS 3.6% KEV · Not listed
Vendors
Products
CVE-2020-12053

In Unisys Stealth 3.4.x, 4.x and 5.x before 5.0.026, if certificate-based authorization is used without HTTPS, an endpoint could be authorized without a private key.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-12051

The CentralAuth extension through REL1_34 for MediaWiki allows remote attackers to obtain sensitive hidden account information via an api.php?action=query&meta=globaluserinfo&guiuser= request. In other words, the information can be retrieved via the action API even though access would be denied when simply visiting wiki/Special:CentralAuth in a web browser.

CVSS 3.1 · 7.5 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2020-12049

dbus: denial of service via file descriptor leak

An issue was discovered in dbus >= 1.3.0 before 1.12.18. The DBusServer in libdbus, as used in dbus-daemon, leaks file descriptors when a message exceeds the per-message file descriptor limit. A local attacker with access to the D-Bus system bus or another system service's private AF_UNIX socket could use this to make the system service reach its file descriptor limit, denying service to subsequent D-Bus clients.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Products
CVE-2020-12048

Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12046

Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s firmware files’ signatures are not verified upon firmware update. This allows an attacker to replace legitimate firmware files with malicious files.

CVSS 3.1 · 5.7 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-12042

Opto 22 SoftPAC Project Version 9.6 and prior. Paths specified within the zip files used to update the SoftPAC firmware are not sanitized. As a result, an attacker with user privileges can gain arbitrary file write access with system access.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-12041

The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot.

CVSS 3.1 · 9.4 Critical EPSS 1.4% KEV · Not listed
Vendors
CVE-2020-12040

Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.

CVSS 3.1 · 2.4 Low EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12038

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.

CVSS 3.1 · 5.5 Medium EPSS 2.6% KEV · Not listed
Products
CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors