Search vulnerabilities

Results 425,994

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

CVSS 3.1 · 7.3 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10625

WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2020-10623

Multiple vulnerabilities could allow an attacker with low privileges to perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10622

LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10621

Multiple issues exist that allow files to be uploaded and executed on the WebAccess/NMS (versions prior to 3.0.2).

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2020-10620

Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC communication does not include any credentials. This allows an attacker with network access to directly communicate with SoftPAC, including, for example, stopping the service remotely.

CVSS 3.1 · 9.8 Critical EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2020-10619

An attacker could use a specially crafted URL to delete files outside the WebAccess/NMS's (versions prior to 3.0.2) control.

CVSS 3.1 · 9.1 Critical EPSS 14.3% KEV · Not listed
Vendors
Products
CVE-2020-10618

LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10617

There are multiple ways an unauthenticated attacker could perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.

CVSS 3.1 · 7.5 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2020-10616

Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC does not specify the path of multiple imported .dll files. Therefore, an attacker can replace them and execute code whenever the service starts.

CVSS 3.1 · 8.8 High EPSS 1.7% KEV · Not listed
Vendors
Products
CVE-2020-10615

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.

CVSS 3.1 · 7.5 High EPSS 2.6% KEV · Not listed
CVE-2020-10614

In OSIsoft PI System multiple products and versions, an authenticated remote attacker with write access to PI Vision databases could inject code into a display. Unauthorized information disclosure, deletion, or modification is possible if a victim views the infected display.

CVSS 3.1 · 4.8 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10613

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.

CVSS 3.1 · 7.5 High EPSS 2.5% KEV · Not listed
CVE-2020-10612

Opto 22 SoftPAC Project Version 9.6 and prior. SoftPACAgent communicates with SoftPACMonitor over network Port 22000. However, this port is open without any restrictions. This allows an attacker with network access to control the SoftPACAgent service including updating SoftPAC firmware, starting or stopping service, or writing to certain registry values.

CVSS 3.1 · 9.1 Critical EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2020-10611

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.

CVSS 3.1 · 9.8 Critical EPSS 5.2% KEV · Not listed
CVE-2020-10610

In OSIsoft PI System multiple products and versions, a local attacker can modify a search path and plant a binary to exploit the affected PI System software to take control of the local computer at Windows system privilege level, resulting in unauthorized information disclosure, deletion, or modification.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10609

Grundfos CIM 500 v06.16.00 stores plaintext credentials, which may allow sensitive information to be read or allow modification to system settings by someone with access to the device.

CVSS 3.1 · 7.5 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2020-10608

In OSIsoft PI System multiple products and versions, a local attacker can plant a binary and bypass a code integrity check for loading PI System libraries. This exploitation can target another local user of PI System software on the computer to escalate privilege and result in unauthorized information disclosure, deletion, or modification.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors