Search vulnerabilities

Results 430,100

CVE-2020-10637

Eaton HMiSoft VU3 (HMIVU3 runtime not impacted), Version 3.00.23 and prior, however, the HMIVU runtimes are not impacted by these issues. A specially crafted input file could trigger an out-of-bounds read when loaded by the affected product.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10634

SAE IT-systems FW-50 Remote Telemetry Unit (RTU). A specially crafted request could allow an attacker to view the file structure of the affected device and access files that should be inaccessible.

CVSS 3.1 · 9.1 Critical EPSS 1.4% KEV · Not listed
Vendors
CVE-2020-10633

A non-persistent XSS (cross-site scripting) vulnerability exists in eWON Flexy and Cosy (all firmware versions prior to 14.1s0). An attacker could send a specially crafted URL to initiate a password change for the device. The target must introduce the credentials to the gateway before the attack can be successful.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10631

An attacker could use a specially crafted URL to delete or read files outside the WebAccess/NMS's (versions prior to 3.0.2) control.

CVSS 3.1 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2020-10630

SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10629

WebAccess/NMS (versions prior to 3.0.2) does not sanitize XML input. Specially crafted XML input could allow an attacker to read sensitive files.

CVSS 3.1 · 7.5 High EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

CVSS 3.1 · 7.3 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10625

WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2020-10623

Multiple vulnerabilities could allow an attacker with low privileges to perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10622

LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10621

Multiple issues exist that allow files to be uploaded and executed on the WebAccess/NMS (versions prior to 3.0.2).

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2020-10620

Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC communication does not include any credentials. This allows an attacker with network access to directly communicate with SoftPAC, including, for example, stopping the service remotely.

CVSS 3.1 · 9.8 Critical EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2020-10619

An attacker could use a specially crafted URL to delete files outside the WebAccess/NMS's (versions prior to 3.0.2) control.

CVSS 3.1 · 9.1 Critical EPSS 14.3% KEV · Not listed
Vendors
Products
CVE-2020-10618

LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10617

There are multiple ways an unauthenticated attacker could perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.

CVSS 3.1 · 7.5 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2020-10616

Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC does not specify the path of multiple imported .dll files. Therefore, an attacker can replace them and execute code whenever the service starts.

CVSS 3.1 · 8.8 High EPSS 1.7% KEV · Not listed
Vendors
Products
CVE-2020-10615

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.

CVSS 3.1 · 7.5 High EPSS 2.6% KEV · Not listed