Filtered by vendor Juniper Subscriptions
Filtered by product Ptx10008 Subscriptions
Total 22 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-36833 1 Juniper 5 Junos Os Evolved, Ptx10001-36mr, Ptx10004 and 2 more 2024-08-02 6.5 Medium
A Use After Free vulnerability in the packet forwarding engine (PFE) of Juniper Networks Junos OS Evolved on PTX10001-36MR, and PTX10004, PTX10008, PTX10016 with LC1201/1202 allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS). The process 'aftman-bt' will crash after multiple flaps on a multicast-only fast reroute (MoFRR) enabled interface. This will cause the respective FPC to stop forwarding traffic and it needs to be rebooted to restore the service. An indication that the system experienced this issue is the following log message:   <date> <hostname> evo-aftmand-bt[<pid>]: [Error] jexpr_fdb: sanity check failed, ... , app_name L3 Mcast Routes This issue affects Juniper Networks Junos OS Evolved on PTX10001-36MR, PTX10004, PTX10008, PTX10016 with LC1201/1202: 21.2 version 21.2R1-EVO and later versions; 21.3 version 21.3R1-EVO and later versions; 21.4 versions prior to 21.4R3-S3-EVO; 22.1 version 22.1R1-EVO and later versions; 22.2 versions prior to 22.2R3-S2-EVO; 22.3 versions prior to 22.3R3-EVO; 22.4 versions prior to 22.4R1-S2-EVO, 22.4R2-EVO.
CVE-2023-22392 1 Juniper 11 Junos, Ptx1000, Ptx1000-72q and 8 more 2024-08-02 6.5 Medium
A Missing Release of Memory after Effective Lifetime vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS). PTX3000, PTX5000, QFX10000, PTX1000, PTX10002, and PTX10004, PTX10008 and PTX10016 with LC110x FPCs do not support certain flow-routes. Once a flow-route is received over an established BGP session and an attempt is made to install the resulting filter into the PFE, FPC heap memory is leaked. The FPC heap memory can be monitored using the CLI command "show chassis fpc". The following syslog messages can be observed if the respective filter derived from a flow-route cannot be installed. expr_dfw_sfm_range_add:661 SFM packet-length Unable to get a sfm entry for updating the hw expr_dfw_hw_sfm_add:750 Unable to add the filter secondarymatch to the hardware expr_dfw_base_hw_add:52 Failed to add h/w sfm data. expr_dfw_base_hw_create:114 Failed to add h/w data. expr_dfw_base_pfe_inst_create:241 Failed to create base inst for sfilter 0 on PFE 0 for __flowspec_default_inet__ expr_dfw_flt_inst_change:1368 Failed to create __flowspec_default_inet__ on PFE 0 expr_dfw_hw_pgm_fnum:465 dfw_pfe_inst_old not found for pfe_index 0! expr_dfw_bp_pgm_flt_num:548 Failed to pgm bind-point in hw: generic failure expr_dfw_bp_topo_handler:1102 Failed to program fnum. expr_dfw_entry_process_change:679 Failed to change instance for filter __flowspec_default_inet__. This issue affects Juniper Networks Junos OS: on PTX1000, PTX10002, and PTX10004, PTX10008 and PTX10016 with LC110x FPCs: * All versions prior to 20.4R3-S5; * 21.1 versions prior to 21.1R3-S4; * 21.2 versions prior to 21.2R3-S2; * 21.3 versions prior to 21.3R3; * 21.4 versions prior to 21.4R2-S2, 21.4R3; * 22.1 versions prior to 22.1R1-S2, 22.1R2. on PTX3000, PTX5000, QFX10000: * All versions prior to 20.4R3-S8; * 21.1 version 21.1R1 and later versions; * 21.2 versions prior to 21.2R3-S6; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S4; * 22.1 versions prior to 22.1R3-S3 * 22.2 versions prior to 22.2R3-S1 * 22.3 versions prior to 22.3R2-S2, 22.3R3 * 22.4 versions prior to 22.4R2.