| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow input passed in the URL that is not properly verified before use, which may allow an attacker to read arbitrary files from local resources. |
| Systech Corporation NDS-5000 Terminal Server, NDS/5008 (8 Port, RJ45), firmware Version 02D.30. Successful exploitation of this vulnerability could allow information disclosure, limit system availability, and may allow remote code execution. |
| In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable to a cross-site request forgery, which may allow an attacker to remotely execute arbitrary code. |
| VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow weak or insecure permissions on the VBASE directory resulting in elevation of privileges or malicious effects on the system the next time a privileged user runs the application. |
| In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is transmitted over some web applications in clear text. |
| Delta Industrial Automation CNCSoft ScreenEditor, v1.00.96 and prior. Multiple stack-based buffer overflows can be exploited when a valid user opens a specially crafted, malicious input file. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed. |
| VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow an unauthenticated attacker to discover the cryptographic key from the web server and gain information about the login and the encryption/decryption mechanism, which may be exploited to bypass authentication of the HTML5 HMI web interface. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered. |
| In Honeywell WIN-PAK 4.7.2, Web and prior versions, the header injection vulnerability has been identified, which may allow remote code execution. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered. |
| In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable due to the usage of old jQuery libraries. |
| In Emerson ValveLink v12.0.264 to v13.4.118, a vulnerability in the ValveLink software may allow a local, unprivileged, trusted insider to escalate privileges due to insecure configuration parameters. |
| Honeywell INNCOM INNControl 3 allows workstation users to escalate application user privileges through the modification of local configuration files. |
| In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network. |
| A privilege escalation issue was discovered in the postUser function in HashBrown CMS through 1.3.3. An editor user can change the password hash of an admin user's account, or otherwise reconfigure that account. |
| A sensitive information disclosure vulnerability in Tableau Server 10.5, 2018.x, 2019.x, 2020.x released before June 26, 2020, could allow access to sensitive information in log files. |