Filtered by CWE-77
Total 2087 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2017-12339 1 Cisco 2 Lan Switch Software, Nx-os 2024-08-05 N/A
A vulnerability in the CLI of Cisco NX-OS System Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments to the CLI parser. An attacker could exploit this vulnerability by injecting crafted command arguments into a vulnerable CLI command. An exploit could allow the attacker to execute arbitrary commands at the user's privilege level. On products that support multiple virtual device contexts (VDCs), this vulnerability could allow the attacker to execute commands at the user's privilege level outside the user's environment. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 3000 Series Switches, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode, Nexus 9000 Series Switches in standalone NX-OS mode, and Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve99925, CSCvf15164, CSCvf15167, CSCvf15170, CSCvf15173.
CVE-2017-12352 1 Cisco 1 Application Policy Infrastructure Controller 2024-08-05 N/A
A vulnerability in certain system script files that are installed at boot time on Cisco Application Policy Infrastructure Controllers could allow an authenticated, local attacker to gain elevated privileges and execute arbitrary commands with root privileges on an affected host operating system. The vulnerability is due to insufficient validation of user-controlled input that is supplied to certain script files of an affected system. An attacker could exploit this vulnerability by submitting crafted input to a script file on an affected system. A successful exploit could allow the attacker to gain elevated privileges and execute arbitrary commands with root privileges on the affected system. To exploit this vulnerability, the attacker would need to authenticate to the affected system by using valid administrator credentials. Cisco Bug IDs: CSCvf57274.
CVE-2017-12330 1 Cisco 1 Nx-os 2024-08-05 N/A
A vulnerability in the CLI of Cisco NX-OS System Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments to the CLI parser. An attacker could exploit this vulnerability by injecting crafted command arguments into a vulnerable CLI command and gaining unauthorized access to the underlying operating system of the device. An exploit could allow the attacker to execute arbitrary commands at the user's privilege level. On products that support multiple virtual device contexts (VDCs), this vulnerability could allow an attacker to execute commands at the user's privilege level outside the user's environment. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 3000 Series Switches, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve99902, CSCvf14879.
CVE-2017-12335 1 Cisco 2 Nx-os, Unified Computing System 2024-08-05 N/A
A vulnerability in the CLI of Cisco NX-OS System Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into a vulnerable CLI command and gain unauthorized access to the underlying operating system of the device. An exploit could allow the attacker to execute arbitrary commands at the user's privilege level. On products that support multiple virtual device contexts (VDCs), this vulnerability could allow an attacker to execute commands at the user's privilege level outside the user's environment. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 3000 Series Switches, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules, Unified Computing System Manager. Cisco Bug IDs: CSCvf14923, CSCvf14926, CSCvg04095.
CVE-2017-12305 1 Cisco 1 Ip Phone 8800 Series Firmware 2024-08-05 N/A
A vulnerability in the debug interface of Cisco IP Phone 8800 series could allow an authenticated, local attacker to execute arbitrary commands, aka Debug Shell Command Injection. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by authenticating to the device and submitting additional command input to the affected parameter in the debug shell. Cisco Bug IDs: CSCvf80034.
CVE-2017-12277 1 Cisco 6 Firepower 4110 Next-generation Firewall, Firepower 4120 Next-generation Firewall, Firepower 4140 Next-generation Firewall and 3 more 2024-08-05 N/A
A vulnerability in the Smart Licensing Manager service of the Cisco Firepower 4100 Series Next-Generation Firewall (NGFW) and Firepower 9300 Security Appliance could allow an authenticated, remote attacker to inject arbitrary commands that could be executed with root privileges. The vulnerability is due to insufficient input validation of certain Smart Licensing configuration parameters. An authenticated attacker could exploit the vulnerability by configuring a malicious URL within the affected feature. A successful exploit could allow the attacker to execute arbitrary commands with root privileges. This vulnerability affects the following Cisco Firepower Security products running FX-OS code trains 1.1.3, 1.1.4, and 2.0.1 (versions 2.1.1, 2.2.1, and 2.2.2 are not affected): Firepower 4100 Series Next-Generation Firewall and Firepower 9300 Security Appliance. Cisco Bug IDs: CSCvb86863.
CVE-2017-11610 4 Debian, Fedoraproject, Redhat and 1 more 5 Debian Linux, Fedora, Cloudforms and 2 more 2024-08-05 N/A
The XML-RPC server in supervisor before 3.0.1, 3.1.x before 3.1.4, 3.2.x before 3.2.4, and 3.3.x before 3.3.3 allows remote authenticated users to execute arbitrary commands via a crafted XML-RPC request, related to nested supervisord namespace lookups.
CVE-2017-9980 1 Greenpacket 2 Dx-350, Dx-350 Firmware 2024-08-05 N/A
In Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb, the "PING" (aka tag_ipPing) feature within the web interface allows performing command injection, via the "pip" parameter.
CVE-2017-9384 1 Getvera 4 Veraedge, Veraedge Firmware, Veralite and 1 more 2024-08-05 N/A
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a web user interface that allows a user to manage the device. As a part of the functionality the device firmware file contains a file known as relay.sh which allows the device to create relay ports and connect the device to Vera servers. This is primarily used as a method of communication between the device and Vera servers so the devices can be communicated with even when the user is not at home. One of the parameters retrieved by this specific script is "remote_host". This parameter is not sanitized by the script correctly and is passed in a call to "eval" to execute another script where remote_host is concatenated to be passed a parameter to the second script. This allows an attacker to escape from the executed command and then execute any commands of his/her choice.
CVE-2017-9388 1 Getvera 4 Veraedge, Veraedge Firmware, Veralite and 1 more 2024-08-05 N/A
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a web user interface that allows a user to manage the device. As a part of the functionality the device firmware file contains a file known as proxy.sh which allows the device to proxy a specific request to and from from another website. This is primarily used as a method of communication between the device and Vera website when the user is logged in to the https://home.getvera.com and allows the device to communicate between the device and website. One of the parameters retrieved by this specific script is "url". This parameter is not sanitized by the script correctly and is passed in a call to "eval" to execute "curl" functionality. This allows an attacker to escape from the executed command and then execute any commands of his/her choice.
CVE-2017-8411 1 Dlink 2 Dcs-1130, Dcs-1130 Firmware 2024-08-05 8.8 High
An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the POST parameters passed in this request (to test if email credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The library "libmailutils.so" is the one that has the vulnerable function "sub_1FC4" that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows an ARM little endian format. The function sub_1FC4 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "receiver1" is extracted in function "sub_15AC" which is then passed to the vulnerable system API call. The vulnerable library function is accessed in "cgibox" binary at address 0x00023BCC which calls the "Send_mail" function in "libmailutils.so" binary as shown below which results in the vulnerable POST parameter being passed to the library which results in the command injection issue.
CVE-2017-8413 1 Dlink 4 Dcs-1100, Dcs-1100 Firmware, Dcs-1130 and 1 more 2024-08-05 8.8 High
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device runs a custom daemon on UDP port 5978 which is called "dldps2121" and listens for broadcast packets sent on 255.255.255.255. This daemon handles custom D-Link UDP based protocol that allows D-Link mobile applications and desktop applications to discover D-Link devices on the local network. The binary processes the received UDP packets sent from any device in "main" function. One path in the function traverses towards a block of code that handles commands to be executed on the device. The custom protocol created by D-Link follows the following pattern: Packetlen, Type of packet; M=MAC address of device or broadcast; D=Device Type;C=base64 encoded command string;test=1111. If a packet is received with the packet type being "S" or 0x53 then the string passed in the "C" parameter is base64 decoded and then executed by passing into a System API. We can see at address 0x00009B44 that the string received in packet type subtracts 0x31 or "1" from the packet type and is compared against 0x22 or "double quotes". If that is the case, then the packet is sent towards the block of code that executes a command. Then the value stored in "C" parameter is extracted at address 0x0000A1B0. Finally, the string received is base 64 decoded and passed on to the system API at address 0x0000A2A8 as shown below. The same form of communication can be initiated by any process including an attacker process on the mobile phone or the desktop and this allows a third-party application on the device to execute commands on the device without any authentication by sending just 1 UDP packet with custom base64 encoding.
CVE-2017-8404 1 Dlink 2 Dcs-1130, Dcs-1130 Firmware 2024-08-05 9.8 Critical
An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the POST parameters passed in this request (to test if email credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The library "libmailutils.so" is the one that has the vulnerable function "sub_1FC4" that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows an ARM little endian format. The function sub_1FC4 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "receiver1" is extracted in function "sub_15AC" which is then passed to the vulnerable system API call. The vulnerable library function is accessed in "cgibox" binary at address 0x0008F598 which calls the "mailLoginTest" function in "libmailutils.so" binary as shown below which results in the vulnerable POST parameter being passed to the library which results in the command injection issue.
CVE-2017-8408 1 Dlink 2 Dcs-1130, Dcs-1130 Firmware 2024-08-05 N/A
An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the GET parameters passed in this request (to test if SMB credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "cgibox" is the one that has the vulnerable function "sub_7EAFC" that receives the values sent by the GET request. If we open this binary in IDA-pro we will notice that this follows a ARM little endian format. The function sub_7EAFC in IDA pro is identified to be receiving the values sent in the GET request and the value set in GET parameter "user" is extracted in function sub_7E49C which is then passed to the vulnerable system API call.
CVE-2017-8333 1 Securifi 6 Almond, Almond\+, Almond\+firmware and 3 more 2024-08-05 N/A
An issue was discovered on Securifi Almond, Almond+, and Almond 2015 devices with firmware AL-R096. The device provides a user with the capability of adding new routes to the device. It seems that the POST parameters passed in this request to set up routes on the device can be set in such a way that would result in passing commands to a "popen" API in the function and thus result in command injection on the device. If the firmware version AL-R096 is dissected using binwalk tool, we obtain a cpio-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "goahead" is the one that has the vulnerable function that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows a MIPS little endian format. The function sub_00420F38 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "dest" is extracted at address 0x00420FC4. The POST parameter "dest is concatenated in a route add command and this is passed to a "popen" function at address 0x00421220. This allows an attacker to provide the payload of his/her choice and finally take control of the device.
CVE-2017-8291 3 Artifex, Debian, Redhat 9 Ghostscript, Debian Linux, Enterprise Linux and 6 more 2024-08-05 7.8 High
Artifex Ghostscript through 2017-04-26 allows -dSAFER bypass and remote command execution via .rsdparams type confusion with a "/OutputFile (%pipe%" substring in a crafted .eps document that is an input to the gs program, as exploited in the wild in April 2017.
CVE-2017-8331 1 Securifi 6 Almond, Almond\+, Almond\+firmware and 3 more 2024-08-05 N/A
An issue was discovered on Securifi Almond, Almond+, and Almond 2015 devices with firmware AL-R096. The device provides a user with the capability of adding new port forwarding rules to the device. It seems that the POST parameters passed in this request to set up routes on the device can be set in such a way that would result in passing commands to a "system" API in the function and thus result in command injection on the device. If the firmware version AL-R096 is dissected using binwalk tool, we obtain a cpio-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "goahead" is the one that has the vulnerable function that recieves the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows a MIPS little endian format. The function sub_43C280in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "ip_address" is extracted at address 0x0043C2F0. The POST parameter "ipaddress" is concatenated at address 0x0043C958 and this is passed to a "system" function at address 0x00437284. This allows an attacker to provide the payload of his/her choice and finally take control of the device.
CVE-2017-7977 1 Unicon-software 1 Elux 2024-08-05 9.8 Critical
The Screensavercc component in eLux RP before 5.5.0 allows attackers to bypass intended configuration restrictions and execute arbitrary commands with root privileges by inserting commands in a local configuration dialog in the control panel.
CVE-2017-7876 1 Qnap 1 Qts 2024-08-05 10 Critical
This command injection vulnerability in QTS allows attackers to run arbitrary commands in the compromised application. QNAP have already fixed the issue in QTS 4.2.6 build 20170517, QTS 4.3.3.0174 build 20170503 and later versions.
CVE-2017-7799 1 Mozilla 1 Firefox 2024-08-05 N/A
JavaScript in the "about:webrtc" page is not sanitized properly being assigned to "innerHTML". Data on this page is supplied by WebRTC usage and is not under third-party control, making this difficult to exploit, but the vulnerability could possibly be used for a cross-site scripting (XSS) attack. This vulnerability affects Firefox < 55.