| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device. |
| An attacker with network access to the affected PLC (CJ-series and CS-series PLCs, all versions) may use a network protocol to read and write files on the PLC internal memory and memory card.
|
| Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). |
| In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a missing authentication allows for full access via API. |
| HCL MyXalytics is affected by a failure to restrict URL access vulnerability. Unauthenticated users might gain unauthorized access to potentially confidential information, creating a risk of misuse, manipulation, or unauthorized distribution. |
|
The cloud provider MachineSense uses for integration and deployment for multiple MachineSense devices, such as the programmable logic controller (PLC), PumpSense, PowerAnalyzer, FeverWarn, and others is insufficiently protected against unauthorized access. An attacker with access to the internal procedures could view source code, secret credentials, and more.
|
| Boodskap IoT Platform v4.4.9-02 allows attackers to make unauthenticated API requests. |
| Mastodon is a free, open-source social network server based on ActivityPub. Mastodon allows new identities from configured authentication providers (CAS, SAML, OIDC) to attach to existing local users with the same e-mail address. This results in a possible account takeover if the authentication provider allows changing the e-mail address or multiple authentication providers are configured. When a user logs in through an external authentication provider for the first time, Mastodon checks the e-mail address passed by the provider to find an existing account. However, using the e-mail address alone means that if the authentication provider allows changing the e-mail address of an account, the Mastodon account can immediately be hijacked. All users logging in through external authentication providers are affected. The severity is medium, as it also requires the external authentication provider to misbehave. However, some well-known OIDC providers (like Microsoft Azure) make it very easy to accidentally allow unverified e-mail changes. Moreover, OpenID Connect also allows dynamic client registration. This issue has been addressed in versions 4.2.6, 4.1.14, 4.0.14, and 3.5.18. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| Missing Authentication for Critical Function in GitHub repository ikus060/rdiffweb prior to 2.5.0a6. |
| Asus RT-N12E 2.0.0.39 is affected by an incorrect access control vulnerability. Through system.asp / start_apply.htm, an attacker can change the administrator password without any authentication. |
| Internet passwords stored in Person documents in the Domino® Directory created using the "Add Person" action on the People & Groups tab in the Domino® Administrator are secured using a cryptographically weak hash algorithm. This could enable attackers with access to the hashed value to determine a user's password, e.g. using a brute force attack. This issue does not impact Person documents created through user registration https://help.hcltechsw.com/domino/10.0.1/admin/conf_userregistration_c.html .
|
| Free5gc v3.2.1 is vulnerable to Information disclosure. |
| Missing authentication for critical function vulnerability in iSCSI management functionality in Synology DiskStation Manager (DSM) before 7.1-42661 allows remote attackers to read or write arbitrary files via unspecified vectors. |
| A vulnerability has been found in TOTOLINK A720R 4.1.5cu.374 and classified as critical. This vulnerability affects unknown code of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument topicurl with the input RebootSystem leads to missing authentication. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. |
| Vulnerability in the Oracle Trade Management product of Oracle E-Business Suite (component: GL Accounts). Supported versions that are affected are 12.2.3-12.2.13. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Trade Management. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle Trade Management accessible data as well as unauthorized access to critical data or complete access to all Oracle Trade Management accessible data. CVSS 3.1 Base Score 8.1 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N). |
| Insufficient validation of untrusted input in VPN in Google Chrome on ChromeOS prior to 106.0.5249.62 allowed a local attacker to bypass managed device restrictions via physical access to the device. (Chromium security severity: Medium) |
| Password recovery vulnerability in SICK SIM1004 Partnumber 1098148 with firmware version <2.0.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.0.0 as soon as possible (available in SICK Support Portal). |
| Password recovery vulnerability in SICK SIM2000ST Partnumber 1080579 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.7.0 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM2000ST. A fix is planned but not yet scheduled. |
| Password recovery vulnerability in SICK SIM4000 (PPC) Partnumber 1078787 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.10.1 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM4000. A fix is planned but not yet scheduled. |
| Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version <2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.2.0 as soon as possible (available in SICK Support Portal). |