| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A low-privilege user may use SQL syntax to write arbitrary files to the OpenClinic GA 5.09.02 and 5.89.05b server, which may allow the execution of arbitrary commands. |
| A flaw was found in the Linux kernel before 5.9-rc4. Memory corruption can be exploited to gain root privileges from unprivileged processes. The highest threat from this vulnerability is to data confidentiality and integrity. |
| Unchecked return value in some Intel(R) Graphics Drivers before version 26.20.100.8141 may allow a privileged user to potentially enable a denial of service via local access. |
| The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. |
| The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. |
| Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. |
| Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. |
| Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI. |
| Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI. |
| Grundfos CIM 500 v06.16.00 stores plaintext credentials, which may allow sensitive information to be read or allow modification to system settings by someone with access to the device. |
| Universal Robots controller execute URCaps (zip files containing Java-powered applications) without any permission restrictions and a wide API that presents many primitives that can compromise the overall robot operations as demonstrated in our video. In our PoC we demonstrate how a malicious actor could 'cook' a custom URCap that when deployed by the user (intendedly or unintendedly) compromises the system |
| The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them). |
| A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges on the server while its configuration can be modified by local users. The vulnerability could allow a local authenticated attacker to execute arbitrary commands on the server with local SYSTEM privileges. |
| Given a compromised sandboxed content process due to a separate vulnerability, it is possible to escape that sandbox by loading accounts.firefox.com in that process and forcing a log-in to a malicious Firefox Sync account. Preference settings that disable the sandbox are then synchronized to the local machine and the compromised browser would restart without the sandbox if a crash is triggered. This vulnerability affects Firefox ESR < 60.9, Firefox ESR < 68.1, and Firefox < 69. |
| Vixie Cron before the 3.0pl1-133 Debian package allows local users to cause a denial of service (daemon crash) via a large crontab file because the calloc return value is not checked. |
| In libskia, there is a possible crash due to a missing null check. This could lead to remote denial of service with no additional execution privileges needed. User interaction is needed for exploitation. Product: AndroidVersions: Android-10Android ID: A-132782448 |
| In MobaTek MobaXterm Personal Edition v11.1 Build 3860, the SSH private key and its password can be retrieved from process memory for the lifetime of the process, even after the user disconnects from the remote SSH server. This affects Passwordless Authentication that has a Password Protected SSH Private Key. |
| Weak default password cause vulnerability in SonicWall Email Security appliance which leads to attacker gain access to appliance database. This vulnerability affected Email Security Appliance version 10.0.2 and earlier. |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords. |
| Moxa IKS and EDS store plaintext passwords, which may allow sensitive information to be read by someone with access to the device. |