Description
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
Published: 2019-08-13
Score: 7.5 High
EPSS: < 1% Very Low
KEV: No
Impact: n/a
Action: n/a
AI Analysis

No analysis available yet.

Remediation

No remediation available yet.

Tracking

Sign in to view the affected projects.

Advisories
Source ID Title
EUVD EUVD EUVD-2019-2657 A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
History

No history.

Subscriptions

Siemens Simatic Et 200sp Open Controller Cpu 1515sp Pc Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware Simatic Et 200sp Open Controller Cpu 1515sp Pc Firmware Simatic S7-1200 Cpu 1211c Simatic S7-1200 Cpu 1211c Firmware Simatic S7-1200 Cpu 1212c Simatic S7-1200 Cpu 1212c Firmware Simatic S7-1200 Cpu 1214c Simatic S7-1200 Cpu 1214c Firmware Simatic S7-1200 Cpu 1215c Simatic S7-1200 Cpu 1215c Firmware Simatic S7-1200 Cpu 1217c Simatic S7-1200 Cpu 1217c Firmware Simatic S7-1500 Cpu 1511c Simatic S7-1500 Cpu 1511c Firmware Simatic S7-1500 Cpu 1512c Simatic S7-1500 Cpu 1512c Firmware Simatic S7-1500 Cpu 1518 Simatic S7-1500 Cpu 1518 Firmware Simatic S7-1500 Software Controller Simatic S7 Plcsim Advanced
cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published:

Updated: 2024-08-04T22:40:15.602Z

Reserved: 2019-04-08T00:00:00.000Z

Link: CVE-2019-10943

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Modified

Published: 2019-08-13T19:15:15.530

Modified: 2024-11-21T04:20:12.313

Link: CVE-2019-10943

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses