Project Subscriptions
| Vendors | Products |
|---|---|
|
Mitsubishielectric
Subscribe
|
Q03udecpu
Subscribe
Q03udecpu Firmware
Subscribe
Q03udvcpu
Subscribe
Q03udvcpu Firmware
Subscribe
Q04udehcpu
Subscribe
Q04udehcpu Firmware
Subscribe
Q04udpvcpu
Subscribe
Q04udpvcpu Firmware
Subscribe
Q04udvcpu
Subscribe
Q04udvcpu Firmware
Subscribe
Q06udehcpu
Subscribe
Q06udehcpu Firmware
Subscribe
Q06udpvcpu
Subscribe
Q06udpvcpu Firmware
Subscribe
Q06udvcpu
Subscribe
Q06udvcpu Firmware
Subscribe
Q100udehcpu
Subscribe
Q100udehcpu Firmware
Subscribe
Q10udehcpu
Subscribe
Q10udehcpu Firmware
Subscribe
Q13udehcpu
Subscribe
Q13udehcpu Firmware
Subscribe
Q13udpvcpu
Subscribe
Q13udpvcpu Firmware
Subscribe
Q13udvcpu
Subscribe
Q13udvcpu Firmware
Subscribe
Q20udehcpu
Subscribe
Q20udehcpu Firmware
Subscribe
Q26udehcpu
Subscribe
Q26udehcpu Firmware
Subscribe
Q26udpvcpu
Subscribe
Q26udpvcpu Firmware
Subscribe
Q26udvcpu
Subscribe
Q26udvcpu Firmware
Subscribe
Q50udehcpu
Subscribe
Q50udehcpu Firmware
Subscribe
|
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2019-16094 | Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash. |
Solution
Mitsubishi Electric has produced a new version of the firmware. Additional information about this vulnerability or Mitsubishi Electric's compensating control is available by contacting a local Mitsubishi Electric representative, which can be found at the following location: https://us.mitsubishielectric.com/fa/en/about-us/distributors Mitsubishi Electric strongly recommends users should operate the affected device behind a firewall.
Workaround
No workaround given by the vendor.
Thu, 26 Jun 2025 17:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash. | Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash and disruption to USB communication. |
Thu, 26 Jun 2025 17:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Title | Mitsubishi Electric MELSEC-Q Series PLCs Resource Exhaustion | |
| References |
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2025-06-26T17:08:15.995Z
Reserved: 2019-01-22T00:00:00
Link: CVE-2019-6535
No data.
Status : Modified
Published: 2019-02-05T19:29:00.243
Modified: 2025-06-26T18:15:21.017
Link: CVE-2019-6535
No data.
OpenCVE Enrichment
No data.
EUVD