HTSlib: Heap buffer overflow in BCF reader due to improper validation of input.
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| samtools | htslib | affected |
|
No data.
No data.
No data available yet.
No CVSS v3.1
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
No EPSS score available.
Key SSVC decision points have not yet been added.
| Type | Values Removed | Values Added |
|---|---|---|
| Description | HTSlib is a library for reading and writing bioinformatics file formats. Prior to 1.21.2, 1.22.3, 1.23.2, and 1.24, the BCF reader can experience an integer overflow in a record-length check that verifies whether a record contains enough bytes for the expected number and size of stored items. A crafted BCF record can bypass this check, causing reads beyond the stored data and, in some cases, writes beyond the heap buffer when the reader sets the least significant bit of accessed bytes. Opening such a file can crash the process, corrupt data or heap structures, and may permit arbitrary code execution. This issue is fixed in versions 1.21.2, 1.22.3, 1.23.2, and 1.24. | |
| Title | HTSlib: Heap buffer overflow in BCF reader due to improper validation of input. | |
| Weaknesses | CWE-122 CWE-125 CWE-1284 CWE-190 CWE-787 |
|
| References |
|
|