| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file. |
| The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port. NOTE: this issue might overlap CVE-2015-3459. |
| Hospira MedNet before 6.1 uses a hardcoded cleartext password to control SQL database authorization, which allows remote authenticated users to bypass intended access restrictions by leveraging knowledge of this password. |
| Hospira MedNet before 6.1 uses hardcoded cryptographic keys for protection of data transmission from infusion pumps, which allows remote attackers to obtain sensitive information by sniffing the network. |
| Hospira MedNet software version 5.8 and prior uses vulnerable versions of the JBoss Enterprise Application Platform software that may allow unauthenticated users to execute arbitrary code on the target system. Hospira has developed a new version of the MedNet software, MedNet 6.1. Existing versions of MedNet can be upgraded to MedNet 6.1. |
| The installation component in Hospira MedNet before 6.1 places cleartext credentials in configuration files, which allows local users to obtain sensitive information by reading a file. |
| IBM QRadar SIEM 7.5 through 7.5.0 Update Pack 13 Independent Fix 02 is vulnerable to privilege escalation due to improper privilege assignment to an update script. |
| IBM QRadar SIEM 7.5 through 7.5.0 Update Pack 13 Independent Fix 02 is vulnerable to stored cross-site scripting. This vulnerability allows an authenticated user to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. |
| A heap overflow vulnerability in D-Link DIR820LA1_FW106B02 allows attackers to cause a denial of service via the config.log_to_syslog and log_opt_dropPackets parameters to mydlink_api.ccp. |
| The administrator password setting of the D-Link DIR-820L 1.06B02 is has Improper Access Control and is vulnerable to Unverified Password Change via crafted POST request to /get_set.ccp. |
| SAP NetWeaver (Visual Composer 7.0 RT) versions - 7.30, 7.31, 7.40, 7.50, without restriction, an attacker authenticated as a non-administrative user can upload a malicious file over a network and trigger its processing, which is capable of running operating system commands with the privilege of the Java Server process. These commands can be used to read or modify any information on the server or shut the server down making it unavailable.
|
| OS Command injection vulnerability in D-Link DIR820LA1_FW105B03 allows attackers to escalate privileges to root via a crafted payload. |
| SAP NetWeaver Application Server ABAP, SAP NetWeaver Application Server Java, ABAP Platform, SAP Content Server 7.53 and SAP Web Dispatcher are vulnerable for request smuggling and request concatenation. An unauthenticated attacker can prepend a victim's request with arbitrary data. This way, the attacker can execute functions impersonating the victim or poison intermediary Web caches. A successful attack could result in complete compromise of Confidentiality, Integrity and Availability of the system.
|
| A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered. |
| An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->domain variable, that has the value of the domain parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection. An attacker can send an HTTP request to trigger this vulnerability. |
| The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root. |
| A path traversal vulnerability in the web interfaces of Buffalo WSR-2533DHPL2 firmware version <= 1.02 and WSR-2533DHP3 firmware version <= 1.24 could allow unauthenticated remote attackers to bypass authentication. |
| A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges. |
| A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges. |
| TP-Link Archer AX21 (AX1800) firmware versions before 1.1.4 Build 20230219 contained a command injection vulnerability in the country form of the /cgi-bin/luci;stok=/locale endpoint on the web management interface. Specifically, the country parameter of the write operation was not sanitized before being used in a call to popen(), allowing an unauthenticated attacker to inject commands, which would be run as root, with a simple POST request. |